Typical Ranges and Alarms:
Gas | Range | Standard Alarm (US) |
Carbon monoxide (H2 filtered) | 0-500ppm | 35ppm |
Ammonia (NH3) | 0-100ppm | 25ppm |
Carbon monoxide (CO) | 0-500ppm | 35ppm |
Carbon dioxide (CO2) | 0-5% | 0.5% |
Chlorine (CL2) | 0-20ppm | 0.5ppm |
Flammable | 0-100% LEL | 10% LEL |
Fluorine (F2) | 0-1ppm | 0.1ppm |
Hydrogen (H2) | 0-2000ppm | N/A |
Hydrogen cyanide (HCN) | 0-25ppm | 2ppm |
Hydrogen fluoride (HF) | 0-10 ppm | 2ppm |
Hydrogen sulfide (H2S) | 0-100 ppm | 10ppm |
Nitric oxide (NO) | 0-100 ppm | 25ppm |
Nitrogen dioxide (NO2) | 0-20 ppm | 3ppm |
Oxygen (O2) | 0-25% | 19.5/23.5% |
Ozone (O3) | 0-1 ppm | 0.1ppm |
Phosphine (PH3) | 0-5 ppm | 0.3ppm |
Phosgene (COCL2) | 0-1 ppm | 0.1ppm |
Sulfur dioxide (SO2) | 0-20 ppm | 2ppm |
Technical Specification:
Size | 90 x 48 x 24 mm (3.5 x 1.9 x 0.95 ins) | |
Weight | Flammable Toxic Oxygen | 138g (4.9oz) |
Typical response times (T90) | Flammable | 20s |
Alarms | Audible | 95dB |
Visible | Dual colors red/ blue flashing LEDs in a gas hazard | |
Vibrating | Internal vibrating alarm | |
Display | Custom LCD with backlight and display of gas concentration. Graphic symbols for battery (with proportional indication of remaining operation time), and display mode. Start up indication when calibration is due within 30 days, calibration overdue or service required. | |
Display modes | Normal display Display recall | Real time gas concentration levels Peak readings and TWA |
Datalogging | Full timed datalogging with adjustable sample rate, set to 1 min. data rate as default. 900 hours storage at 1 min. interval (54,000 logs), >4800 events | |
Battery | Rechargeable | Lithium battery for all gas types |
Non rechargeable | Lithium battery for toxics and oxygen (excluding CO2) ETO | |
Operating time* | Rechargeable | 12 hours minimum for flammable unit |
Non rechargeable | Up to 2 years | |
Sampling | Optional manual aspirator | |
Operating temperature range | ** | |
Humidity | 20-90% RH | |
Ingress protection | IP65 | |
Approval codes | Europe | Toxic or O2: ATEX II 1G Ex ia IIC T4 Ga (-20OC Ta +65OC) BASEEFA04ATEX0384 Flammable: ATEX II 2G Ex ia d IIC T4 Gb (-20OC Ta +65OC) BASEEFA04ATEX0383 |
International | Toxic or O2: IECEx BAS05.0039 | |
North America | CSA Class 1 Groups A,B,C,D Division 1 | |
Standards safety | Europe North America | EN60079-0, EN60079-11, EN60079-1, 94/9/ECCSA22.2, 152 |
Operation standards | EN50270, EN50271, IEC61508, EN61779, EN45544 | |
PC interface | RS232 connection from interface module in charger RS232/USB converter available | |
Calibration | Gasman can be routinely calibrated using Portables PC software or by using Checkbox IMH | |
Accessories | Gasman is supplied with an integral alligator clip |